Flow Process Training System
Key Features:
PSA and PXA key specifications at a glance RF performance PSA PXA Frequency range 3 Hz to 6.7 GHz 3 Hz to 13.2 GHz 3 Hz to 26.5 GHz 3 Hz to 42.98 GHz 3 Hz to 44 GHz 3 Hz to 50 GHz 3 Hz to 3.6 GHz 3 Hz to 8.4 GHz 3 Hz to 13.6 GHz 3 Hz to 26.5 GHz 3 Hz to 43 GHz 3 Hz to 44 GHz 3 Hz to 50 GHz TOI 2 GHz 10 GHz 50 GHz +17 dBm +8 dBm +12.5. Piano Chords In The Key Of A Flat Minor Natural. The following piano key chord chart shows all the triads in A flat minor as well as four note extended chords. Let’s now take a look at common chord progressions in the key of Ab minor natural. They are as follows: i – VI – VII (Abm – Fb – Gb) i – iv – VII (Abm – Dbm – Gb).
- Demonstrates automatic control of flow using proportional, proportional plus integral, and proportional, integral plus derivative (PID) control
- Uses industry-standard parts to make it ideal for industrial, vocational and academic training
- Demonstrates operation, calibration and tuning of controllers, transmitters, converters and valves
- Compact, mobile and fully self-contained
- Connects to the TE3300/02 Pressure Process and TE3300/04 Level Process Training Systems for cascade control
- Connects to the TE3300/06 Computer Control System for distributed control
- Safe, practical and realistic
Description:
- The Flow Process Training System is a compact and mobile unit for a wide range of experiments in flow control. It gives students a greater understanding of the stability of simple control systems.
- The main parts of the Flow Process Training System are:
- Industrial controller with auto-tune feature
- Two-channel chart recorder
- A gap-type (rotameter) fl ow meter
- Fixed orifi ce and pressure transmitter
- Pneumatic control valve
- Three-speed pump
- Reservoir
- To carry out experiments, students fill the reservoir with clean water and prime the system. They then set the controller to regulate the flow of the water using a pneumatic valve. The gap-type flow meter gives a visual indication of flow. The fixed orifice and pressure transmitter give feedback to the controller. For a realistic experience, the equipment has industrial-standard instrumentation and parts.
- The apparatus includes two gate valves. One valve controls the fl ow at the output (drain) and the other acts as a flow-bypass valve. A chart recorder shows and logs the changes of the process variable (level) and the controller output.
Learning Outcomes:
- Proportional, integral and derivative control
- Setting up and demonstrating automatic control
- The principles of loop control and the calibration and tuning of controllers, transmitters, converters and valves
- Calibration of an orifice flow meter with a differential pressure transmitter
- Quadratic flow laws and square root extraction
- Cascade control of pressure and flow, and level and fl ow (when used with the TE3300/02 and TE3300/04)
- Distributed control (when used with the TE3300/06 Computer Control System)
Specifications
Electrical supply:
- Single-phase 230 V at 0.3 A or 110 V at 0.6 A, 50/60 Hz (determined by order)
Dimensions and weight:
Dbm Auto Tune Key Finder
- 700 mm x 800 mm x 1750 and 120 kg
Dbm Auto Tune Keyboard
For details see the catalog below: